Senseible

Balakati's brass and bell metal units burn coal and charcoal: how is that counted?

As two numbers. A Balakati unit with a 25 kg crucible emits about 25 t of fossil CO2 a year from coal and power, roughly 3.4 kg per kg of brass. Its charcoal adds about 40 t of biogenic CO2, reported beside that total, not in it.

How the cluster works

Which line each fuel goes on

Charcoal has a hidden upstream cost

Making charcoal in kilns releases methane, which is not biogenic CO2. It sits upstream of your unit, in the charcoal you buy, and belongs in a full product footprint.

Where the energy goes down

Melting takes about 60 MJ per kg of product. A redesigned melting furnace could save 20 to 30%, and a simple temperature indicator stops the melt being held 200 C hotter than needed. A chimney and exhaust fan also clear the furnace room.

One 25 kg crucible unit, one year (estimate)

Fuel and output from TERI's 2016 cluster profile. Coal at India's BUR-2 factor; charcoal at the IPCC default. Brass scrap and its own footprint are not included.

What Senseible does here

The calculators turn your coal and electricity into fossil CO2; keep the charcoal tonnes beside it as the biogenic line.

Sources: TERI, Cluster profile report: Balakati brass industries (2016), GHG Protocol Corporate Standard (biogenic CO2 reported separately), IPCC 2006 Guidelines, Volume 2 Energy (fuel emission factors), CEA, CO2 Baseline Database for the Indian Power Sector (grid factor 0.675 kg CO2 per kWh, FY 2025-26)

Last reviewed 2026-10-31.