Senseible

How do I calculate CO2 per tonne of carbon black?

Use a carbon balance: take the carbon in all feedstock oil and gas fed to the reactors, subtract the carbon leaving in carbon black and any other sold stream, and multiply by 44/12. Divide by tonnes produced. Compare it with the IPCC 2006 default for the furnace black process, 2.62 t CO2 per tonne.

The carbon balance formula

The 2006 IPCC Guidelines, Volume 3, Chapter 3, Section 3.9, cover petrochemical and carbon black production. The mass balance method there tracks carbon in and carbon out.

CO2 = (feedstock oil x its carbon fraction + gas x its carbon fraction) minus (carbon black x its carbon fraction + carbon in any other sold product) x 44/12.

The 44/12 converts a mass of carbon to the mass of CO2 it forms. Carbon that is not in a sold product ends up as CO2 when tail gas is burnt in your dryers, boilers, power plant or flare.

If you cannot run a balance yet, the same section gives a Tier 1 default for the furnace black process of 2.62 t CO2 per tonne of carbon black (Table 3.23, primary and secondary feedstock together). It is a fallback for a national inventory, not a substitute for your own figure in a buyer's footprint.

Where each number comes from

Count feedstock oil once

Feedstock oil is a raw material, not boiler fuel. If its invoices are also entered as fuel burnt, its carbon is counted twice. Keep feedstock in the carbon balance and put only fuels burnt for other purposes, such as diesel for a DG set or a forklift, in the fuel lines.

Grid electricity is separate: kWh x 0.710 kg CO2 per kWh for location-based Scope 2.

Turning it into a product footprint for a tyre buyer

Illustrative month, per tonne of carbon black

Oil and gas quantities and all carbon fractions are illustrative assumptions. Use your own lot analyses and production records.

What Senseible does here

Senseible reads the invoices for feedstock oil, natural gas, diesel and electricity, so the quantities in your carbon balance trace back to dated documents. Grid electricity is converted at 0.710 kg CO2 per kWh, and the carbon balance itself uses your lab carbon fractions.

Sources: 2006 IPCC Guidelines, Volume 3 Industrial Processes, Chapter 3, Section 3.9 Petrochemical and carbon black production, ISO 14067:2018, Carbon footprint of products, CEA CO2 Baseline Database, version 21.0

Last reviewed 2026-10-18. IPCC 2006 Volume 3, Table 3.23 furnace black default (2.62 t CO2/t) checked 2026-10-19 via the IPCC Emission Factor Database; recheck if the 2019 Refinement is cited instead.