Senseible

Can an Andaman or Lakshadweep factory use CEA's Indian grid emission factor?

No. CEA's CO2 Baseline Database leaves out stations in the Andaman and Nicobar Islands and Lakshadweep because they are not connected to the Indian grid. Their power systems are stand-alone, so the national 0.675 kg per kWh for FY 2025-26 does not describe them.

What CEA says

What follows

The Indian grid factor is the weighted average of the grid your mainland plant draws from. An island plant draws from a different system, so using that factor applies a number from a grid it is not on.

What to do instead

  1. Ask your electricity supplier whether it publishes an emission rate for the year.
  2. If it does not, tell the buyer, state which factor you used and why, and keep the bills.
  3. Count any diesel your own generator burns as Scope 1, from the fuel invoices.

Do not

Do not apply 0.675 silently and call it the island figure.

What the wrong number looks like (made-up bill)

Example only.

What Senseible does here

Senseible's calculators apply the CEA grid factor to a bill by financial year, 0.675 kg CO2 per kWh for FY 2025-26. Do not rely on it for island bills; say so in the report.

Sources: CEA, CO2 Baseline Database for the Indian Power Sector, User Guide version 22.0 (August 2026), section 3

Last reviewed 2026-11-03. CEA publishes a new version each year; check the current user guide.