About 14,934 kWh a year in BEE's Ahmedabad report: a 5 HP direct drive vertical agitator replaces a 15 HP belt driven horizontal one drawing 8.5 kW for 12 hours a day. That is about 10 t CO2 on today's grid. Cost Rs 1.25 lakh, payback 1.56 years at 2010 power prices.

The agitator being replaced

The replacement

Two checks on the 14,934 kWh

Where it sits in the unit's footprint

A typical unit in the report used 130,000 kWh and 350 t of wood a year: 1.2 kWh and 3 kg of wood per kg of product, with wood firing hot air generators for drying. One agitator saves about a tenth of the unit's power. Wood CO2 is biogenic and reported separately, so the grid is most of the unit's fossil figure.

One agitator, one year

Grid at CEA's FY 2025-26 factor, an estimate.

What Senseible does here

Senseible reads your electricity bills into monthly records linked to each bill, with CO2 by the CEA factor for the bill's year, so the before and after months sit side by side. For a loan on the agitator, the green loan check lists the papers a lender will want.

Sources: BEE, Detailed project report: energy efficient vertical agitator (6000 litre), Ahmedabad chemical cluster (2010, SAMEEEKSHA), CEA CO2 Baseline Database, version 22.0

Last reviewed 2026-11-01. Report figures are from a BEE SME programme project report; costs and paybacks are at the report year's prices. Check today's tariff and a current quote.