How do I count CO2 from burning coal washery rejects in a power plant?

The same way as coal: tonnes burnt times carbon content times 44/12. Rejects carry much more ash and much less energy than run of mine coal, so the CO2 per tonne is lower but the CO2 per kWh is usually higher. Use a lab analysis of the rejects you burn, not a coal default.

Calculation

Why per kWh can rise

High ash lowers boiler efficiency and raises auxiliary power, so more fuel carbon is burnt for each kWh sent out. Calculate per kWh from your own heat rate.

Who reports it

The plant burning the rejects reports the CO2 as Scope 1. The washery that sells them does not count it again.