Senseible

I leased out a machine for part of the year: how much goes into Category 13?

Only the months it was leased out. The GHG Protocol says a lessor that leases an asset for part of the reporting year accounts for emissions from that portion of the year. Months the machine ran in your own unit stay in your Scope 1 or 2; the leased months go in Category 13.

Split the year by who ran the machine

  1. Write the lease start and end dates against your reporting year, usually April to March.
  2. Months the machine ran in your own shop: its power is already on your electricity bill (Scope 2) and any diesel on your fuel invoices (Scope 1). Nothing goes in Category 13 for these months.
  3. Months a customer ran it under the lease: these go in Category 13, unless your consolidation approach already puts the leased asset in your Scope 1 or 2.
  4. Months it sat idle in your godown with no power drawn: nothing to count.
  5. If a lease starts or ends mid-month, split that month by days so no day lands in both places.

What to ask the lessee for

The calculation guidance points lessors to the same methods as upstream leased assets and notes that you may need to request fuel or usage data from the lessee. For a machine, that means sub-meter kWh for the leased months, or litres of diesel for a genset or compressor.

If the lessee only knows the total for its whole unit, the share has to be allocated. The guidance's own example splits a lessee's 9,000 kg CO2e across two factories by floor space: 9,000 x 5,000 / 15,000 = 3,000 kg CO2e for the leased factory. For a single machine, hours run against the unit's total is a more natural basis; state the one you use.

Leasing out many units? Category 11 is an option

The Scope 3 Standard lets a company treat products it leases to customers the same way as products it sells: report the total expected lifetime emissions of all units leased out that year in Category 11, use of sold products. If you do that, leave those units out of Category 13, so the same emissions are not counted twice.

Points to watch

Worked example: a 15 kW VMC leased out from 1 August to 31 March, FY 2025-26

kWh figures are an example. 0.675 kg CO2 per kWh is the India grid factor for FY 2025-26 (CEA CO2 Baseline Database, version 22.0).

What Senseible does here

Senseible reads the electricity bills and fuel invoices for the months the machine ran in your own unit, so your Scope 1 and 2 cover exactly those months. Keep the lessee's meter or fuel records for the leased months alongside them as your Category 13 evidence.

Sources: GHG Protocol Technical Guidance for Calculating Scope 3 Emissions, Category 13: Downstream leased assets, GHG Protocol Scope 3 Standard (2011), section 5.5 and table 5.4, CEA, CO2 Baseline Database for the Indian Power Sector, version 22.0

Last reviewed 2026-10-31.