How much fuel can a dye house save by recovering heat from hot drain water?

Heat recovered = flow x 4.186 kJ per kg per degree C x (drain temperature minus fresh water temperature) x exchanger effectiveness. With 200 kL a day of 70 degree C drain heating 28 degree C fresh water at 60% effectiveness, that is about 21 GJ a day, or about 30 GJ of boiler fuel.

What sets the saving

From recovered heat to fuel and CO2

Fuel saved = heat recovered / boiler efficiency, provided that fresh water would otherwise have been heated with steam to at least the preheated temperature. CO2 avoided = fuel energy x the fuel's IPCC 2006 factor per GJ. BEE Guide Book 2, in its waste heat recovery chapter, uses the same heat balance.

What cuts the real saving

A side benefit at the ETP

Cooler effluent suits the biological stage of an ETP, which works poorly when wastewater is too hot. Treat this as a side benefit, not part of the fuel saving.

Worked example: 200 kL a day of hot drain

Flows, effectiveness, boiler efficiency and pump power are illustrative. Use measured drain flows and temperatures. The fuel line stays in GJ because the per-kg coal factor of 2.42 assumes coal of about 25.6 MJ per kg; weaker coal emits less per kg.

What Senseible does here

Senseible reads boiler fuel invoices and electricity bills, so the fuel saved and the extra pump power both show in the monthly Scope 1 and 2 records. Drain flows and temperatures come from your own measurements.

Sources: BEE Guide Book 2, Energy Efficiency in Thermal Utilities, Chapter 8 Waste Heat Recovery, 2006 IPCC Guidelines, Volume 2 (Energy), Chapter 2, Table 2.2