What are the seven steps of a GHG inventory quality system?
The GHG Protocol Corporate Standard lists seven: set up an inventory quality team, write a quality management plan, run generic checks, run source-specific checks, review the final inventory, feed findings back to the team, and set up reporting, documentation and archiving. Each is small enough for a one-person plant.
The seven steps
- Establish an inventory quality team or a named manager, who deals with business units, facilities and outside parties such as verifiers.
- Develop a quality management plan covering every level, from data collection to final reporting. Build on any existing quality procedures.
- Perform generic quality checks on data handling, documentation and calculations.
- Perform source-specific checks, such as whether electricity bills or meter readings are the better source of consumption data.
- Review the final inventory: a technical review first, then a managerial review that secures approval.
- Feed the review results back to the person or team from step one, correct errors and make the improvements.
- Set up record keeping: what is documented for internal use, how it is archived and what is reported outside.
What generic checks look like
- Check a sample of input data for transcription errors.
- Keep version control on electronic files.
- Check that units are labelled and carried through every step, and that conversion factors are right.
- Keep input data and calculated data visibly apart in the spreadsheet.
- Check some calculations with a quick back of the envelope sum.
Scale it down
A plant with one person on the inventory can still do all seven. The team is the person, the plan is one page, the generic checks are a monthly tick list, and the review is the owner reading the total before it leaves the building.
Example: a quick sum catches a slip (example figures)
- Spreadsheet shows furnace oil 5,000 L at 2.97 kg CO2 a litre giving 148.5 tonnes (t) CO2
- Quick check: 5,000 x 2.97 = 14,850 kg = 14.85 t CO2
- The sheet is ten times too high: a decimal slip. Fix it, note the fix and the date.
Example figures to show the check. Furnace oil at 2.97 kg CO2 a litre is Senseible's published factor.
What Senseible does here
Senseible checks each record against rules (a missing quantity or unit, an unusual quantity, a low reading confidence) and re-checks the arithmetic. Passing means the rules were met against the evidence; it is not an outside audit.
Sources: GHG Protocol Corporate Accounting and Reporting Standard, revised edition, Chapter 7
Last reviewed 2026-11-04. Based on the revised edition of the Corporate Standard.