Senseible

Can an industrial heat pump replace my boiler for process heat below 90 C, and how much CO2 does it save on India's grid?

Often yes for hot water and low-temperature process heat below 90 C. On India's grid factor of 0.710 kg CO2 per kWh, a heat pump beats a diesel, furnace oil or coal boiler at a coefficient of performance (COP) above about 2.3, but needs a COP above about 3.1 to beat an efficient PNG boiler.

The two formulas, per kWh of useful heat

Break-even COP by fuel

Divide 0.710 by the boiler figure per kWh of heat. With labelled efficiency estimates:

What sets the COP

COP falls as the temperature lift grows, the gap between the heat source and the delivery temperature. Lifting waste heat at 35 to 40 C, such as chiller condenser heat or warm effluent, to 70 to 80 C gives a far better COP than taking heat from outdoor air and delivering it at 90 C. Ask the supplier for the COP at your source and delivery temperatures, not a headline rating.

If the same unit also gives you useful cooling, such as for a dairy's chilling, the combined benefit is larger than the heating figure alone.

Where a heat pump does not fit

Decision rule

Replace coal, furnace oil or diesel heat for duties below 90 C when the supplier's COP at your temperatures is above about 2.5. Against PNG, look for a COP above 3.5 or a waste heat source, or plan on renewable electricity for the heat pump. Check the result from bills after a full season.

Worked example: 500,000 kWh of hot water heat a year

Boiler efficiencies and COPs are labelled estimates. Diesel at about 10.05 kWh per litre is derived from 2.68 kg CO2 per litre and the IPCC default of 74,100 kg CO2 per TJ. Factors are CO2 only.

What Senseible does here

Senseible reads electricity bills and fuel invoices and applies the CEA factor of 0.710 kg CO2 per kWh and IPCC 2006 fuel defaults, so you can compare before and after periods from your own documents. Savings claims stay your own.

Sources: CEA CO2 Baseline Database for the Indian Power Sector, version 21.0, 2006 IPCC Guidelines, Volume 2 Energy, Chapter 2 Stationary Combustion, IEA Heat Pumping Technologies TCP, Annex 58: High-Temperature Heat Pumps

Last reviewed 2026-10-18. The CEA grid factor is revised each year; break-even COPs fall as the grid gets cleaner.