How do I count air conditioner and chiller gas top-ups in the Higg Facility Environmental Module (Higg FEM)?

Count the kilograms of gas you added to each machine in the year, since, in general, the Higg FEM guide treats gas added as gas released. Enter it by gas type, from invoices or service records. The form multiplies by its own warming figure, for example 1,960 for R-22.

What the guide asks

The warming figure the form uses

A global warming figure says how many times more than carbon dioxide a gas traps heat over 100 years, like a strength rating for each gas. In Cascale's FEM 2024 paper the kilograms of carbon dioxide equivalent (CO2e) per kilogram are R-22 1,960, R-410A 2,256, R-134a 1,530, R-407C 1,908 and R-404A 4,728. The paper says an empty factor value results in 0 kilograms of CO2e per kilogram of refrigerant.

If you want a leak rate

The guide's formula: kilograms added divided by the full charge, divided by days between top-ups over 365, times 100%. Its chiller example: 1 kilogram added, full charge 5 kilograms, 275 days, a leak rate of 26.5%, so about 1.33 kilograms lost in a year.

Two machines, one year

Quantities are an example. Figures are the FEM 2024 paper's and the guide's.

What Senseible does here

Senseible reads fuel invoices and electricity bills into monthly records. Senseible keeps refrigerant invoices as evidence but calculates no figure from them, so keep technician job cards with your own records.

Sources: Cascale, Higg FEM How to Higg Guide 2026 (English), Cascale, FEM 2024 Energy and Global Warming Calculations