How do I prove the energy and CO2 savings from an efficiency project, such as a new compressor or motor?
Set a baseline from at least 12 months of metered energy before the project, model how it varies with production or hours, then compare actual use after the project with what the baseline predicts for the same conditions. The difference is the saving. Multiply kWh saved by the grid factor to get CO2.
Why before minus after is not enough
If output rose 10% after you installed a new compressor, raw kWh may barely fall even though the machine is far better. If output fell, raw kWh will overstate the saving. Measurement and verification standards, such as ISO 50015 and the IPMVP protocol, therefore compare actual use with an adjusted baseline: what the old system would have used under the new conditions.
Choose a measurement boundary
- Retrofit isolation: meter just the compressor or motor. Best when the project is small compared with the site, since a whole-site bill hides it. IPMVP calls these Options A and B.
- Whole facility: use the main discom meter. Workable when the expected saving is large compared with normal month to month swings in the bill, and little else changes; check the current IPMVP guidance for how large. IPMVP Option C.
- Record the boundary, the meters used and their calibration dates before the project starts.
Build the baseline
- Collect 12 months of energy before the project, so every season and production cycle is included.
- Collect the variable that drives energy in the same months: tonnes produced, machine hours or, for cooling, temperature.
- Fit the relationship. The simplest is specific energy consumption (kWh per tonne); where there is a large fixed load, use a regression with a fixed and a variable part, as ISO 50006 discusses for energy baselines.
- Note any one-off events, such as a shutdown, and adjust or exclude those months with a written reason.
Report the saving
After commissioning, apply the baseline model to the reporting period's production, subtract actual metered use, and convert. For grid power in India use 0.710 kg CO2 per kWh from the CEA CO2 Baseline Database; for diesel saved use 2.68 kg CO2 per litre. Report savings as measured for the period, not as a lifetime projection, and repeat each year.
Worked example: a compressor replacement
- Baseline year: 240,000 kWh for 4,000 t produced = 60 kWh per t
- Reporting year: 4,400 t produced, 220,000 kWh metered
- Adjusted baseline: 4,400 x 60 = 264,000 kWh
- Saving: 264,000 minus 220,000 = 44,000 kWh
- CO2: 44,000 x 0.710 = 31,240 kg, about 31.2 t CO2
Raw kWh fell only 20,000; the production adjustment shows the real saving. A flat kWh per tonne assumes no fixed load; check that with a regression first.