Senseible

What default carbon dioxide factor does the Intergovernmental Panel on Climate Change give for lime, and does it change with the type of lime?

The Intergovernmental Panel on Climate Change (IPCC) 2006 Guidelines give 0.75 tonnes of carbon dioxide (CO2) per tonne of lime as the Tier 1 default, from an assumed 85% high-calcium and 15% dolomitic mix. By type: high-calcium 0.75, dolomitic 0.86 or 0.77, hydraulic 0.59.

The three lime types in the table

Where the single 0.75 comes from

With no data on lime types, assume 85% high-calcium and 15% dolomitic: 0.85 x 0.75 + 0.15 x 0.77 = 0.6375 + 0.1155 = 0.75 tonnes of CO2 per tonne of lime. Hydraulic lime is assumed zero unless you know otherwise.

Two corrections in the guide

Use your own assay instead of the default

At Tier 2 the factor is 0.785 times the CaO content of your lime from a lab assay, so a lime at 88% CaO is 0.69, not 0.75. The factor covers only the CO2 released from the stone. Kiln fuel is a separate line, added from your fuel invoices.

A kiln making 5,000 tonnes of high-calcium lime a year

Production and the 88% assay are example numbers. Use your own production log and lab report.

What Senseible does here

Senseible reads fuel invoices and electricity bills into monthly records, so the kiln's fuel and power are on file. Process CO2 from the stone comes from your lab assay and production log, which you keep beside them.

Sources: IPCC, 2006 Guidelines for National Greenhouse Gas Inventories, Volume 3, Chapter 2: Mineral Industry Emissions

Last reviewed 2026-11-04. The 2006 Guidelines are written for national inventories. A plant's own lab assay, production log and fuel invoices replace these defaults wherever you have them.