How much fuel does better furnace insulation or ceramic fibre lining save in a reheating or heat-treatment furnace?

Work it out from the furnace's outer wall temperature before and after. Wall heat loss falls sharply as the surface cools: in an illustrative 40 m2 furnace, cutting the casing from 120 C to 70 C saves about 38 tonnes of furnace oil a year. Batch furnaces also save the heat a heavy lining soaks up each cycle.

Wall loss: the BEE surface formula

The BEE guide book on thermal utilities estimates heat lost from a hot surface as S = [10 + (Ts minus Ta) / 20] x (Ts minus Ta) kcal per hour per m2, where Ts is the casing temperature and Ta the surrounding air, both in C. Multiply by the casing area and operating hours for heat lost a year.

To turn heat into fuel, divide by the fuel's calorific value and by the share of fuel heat that stays in the furnace after flue gas losses. Dividing by overall furnace efficiency instead would overstate the saving.

Storage loss in batch furnaces

A furnace that heats up and cools down every shift or batch also heats its own lining each time. That heat is mass of lining x specific heat x temperature rise, and it is lost on every cycle. Ceramic fibre is far lighter than firebrick, so it stores much less heat; this is often the larger saving for bogie hearth and heat-treatment furnaces that cycle daily.

A continuous reheating furnace running round the clock gains little on storage loss; its saving is mostly wall loss.

What to measure

Losses insulation does not fix

Open doors and gaps radiate heat directly from inside the furnace, and poor air to fuel ratio sends heat up the stack. Fix door seals, keep doors shut between charges and tune the burner before or alongside relining, and measure the result with fuel per tonne heated, not the formula alone.

Illustrative example: 40 m2 of furnace casing, furnace oil fired

Calorific value, the 50 percent heat retained, density, hours and temperatures are assumptions for illustration. Confirm the saving from fuel per tonne heated before and after.

What Senseible does here

Senseible reads electricity bills and fuel invoices and applies the CEA grid factor (0.710 kg CO2 per kWh, version 21.0) and IPCC 2006 fuel defaults, so you can compare the months before and after a project from your own documents. The saving you claim, and the engineering behind it, stay your own figures.

Sources: BEE Guide Book 2, Energy Efficiency in Thermal Utilities, furnaces and insulation and refractories chapters, 2006 IPCC Guidelines, Volume 2, Energy (fuel CO2 defaults)