How much electricity does the Warangal rice mill cluster use, and what does one mill's share look like?

The 110 mills in Warangal town used 17.65 million kWh for about 6 lakh t of rice, roughly 12,000 t CO2 a year. A 1 t an hour raw rice mill uses 38.6 kWh per tonne, well above the 17 to 23 kWh benchmark; a 2 t an hour mill uses 23.1.

Three kinds of mill

kWh per tonne of rice, by mill

Work out your own share

  1. Add the year's kWh from your bills, and DG diesel if any.
  2. Divide by tonnes of rice out, not paddy in, to compare with the figures above.
  3. Multiply kWh by 0.675 and diesel litres by 2.645 for fossil CO2.
  4. Show husk burnt as tonnes on a separate biogenic line.

Husk you sell

Husk sold to a power plant or another mill leaves with its carbon. Record tonnes sold and to whom; the buyer, not you, reports burning it.

One mill of each kind (estimate)

Per mill figures are the study group averages in BEE's energy conservation manual for the Warangal cluster; CO2 at the CEA FY 2025-26 grid factor.

What Senseible does here

Put your kWh and tonnes into the calculators for a per tonne figure; Senseible can read a season's electricity bills into one record so the comparison holds next year.

Sources: BEE SME programme, Manual on energy conservation measures in rice milling cluster, Warangal, CEA, CO2 Baseline Database for the Indian Power Sector (grid factor 0.675 kg CO2 per kWh, FY 2025-26), IPCC 2006 Guidelines, Volume 2 Energy (fuel emission factors)