Cloud and data centre emissions calculator
8,760 vCPU-hours on AWS in India, with 2 TB of storage and 500 GB sent out, uses about 24 kWh and emits about 16 kg CO2e.
Calculate server, cloud and data-centre emissions by region, with location-based and market-based Scope 2 figures using published PUE and grid factors.
The formula
kWh = usage × the energy each unit draws × the data centre's PUE. kg CO2e = kWh × the grid factor of the country the region sits in.
Worked example
- Energy: 24 kWh, PUE 1.135.
- 24 kWh × 0.675 kg per kWh = 16 kg CO2e.
16 kg CO2e, location-based.
How to use it
- Add one line per account, workload or server room.
- Pick the provider and the country the region sits in.
- Type vCPU-hours, storage and data out from the bill.
- Add a renewable share only if you hold certificates or a PPA.
- Read kWh and CO2e, location-based and market-based.
Questions people ask
Which scope do cloud emissions belong to?
Owned or colocated servers you pay the power for are Scope 2. Public cloud purchased as a service is Scope 3 Category 1 for your organisation, though the same energy calculation underlies both. This calculator reports the energy and the emissions; the scope placement depends on your operational boundary.
Why are location-based and market-based different?
Location-based uses the physical grid factor of the hosting region. Market-based reflects contractual instruments you hold (RECs, PPAs). GHG Protocol requires both to be disclosed where market instruments are claimed.
Why does the calculator not apply my provider's 100% renewable claim?
A provider's corporate renewable claim is not a contractual instrument held by your organisation. It is shown as reference information only and never applied to your figures automatically.
Are hardware manufacturing emissions included?
No. Embodied emissions of servers and storage are out of scope for this calculation and are stated as an exclusion in the results.
Where do the energy figures come from?
Published per-unit energy figures for compute, memory, storage and data out, times the data-centre overhead each provider publishes (PUE), times the grid factor of the country the region sits in.