How does an Ambur tannery count boiler and effluent plant emissions?
Boiler fuel burned on site is Scope 1: coal, wood or oil times its factor. Electricity for drums, the effluent plant and dryers is Scope 2 at 0.675 kg CO2 per kWh for FY 2025-26. A shared effluent plant you pay for is Scope 3; your own plant's electricity stays in Scope 2.
Steps
Coal in kg x 2.44 kg CO2 per kg (IPCC default for other bituminous coal), or wood handled as biogenic.
Electricity kWh x 0.675 kg CO2 per kWh for FY 2025-26.
Charges from a common effluent plant: Scope 3, from its operator's figure.
Per unit of leather
Divide by square feet or kg finished, and say which you used.
Worked example: one month
- Boiler coal: 15,000 kg x 2.44 = 36,600 kg CO2
- Electricity incl. own ETP: 20,000 kWh x 0.675 = 13,500 kg CO2
- Total: 36,600 + 13,500 = 50,100 kg CO2
Quantities are example values; use your coal invoices and electricity bills.
What Senseible does here
Senseible reads electricity bills (CEA grid factor 0.675 kg CO2 per kWh for FY 2025-26, CO2 Baseline Database version 22.0) and diesel, LPG and gas invoices (IPCC 2006 defaults) into a dated, fingerprinted Scope 1 and 2 record for each site. Intensity per unit uses the activity count you enter, and estimates are labelled as estimates.
Sources: IPCC 2006 Guidelines, Volume 2 Energy, CEA CO2 Baseline Database for the Indian Power Sector, GHG Protocol Corporate Standard
Last reviewed 2026-10-21.