How do I calculate the carbon footprint of a bank branch?
Add each branch's electricity at 0.675 kg CO2 per kWh for FY 2025-26, generator diesel at 2.68 kg per litre and AC refrigerant top-ups. Sum branches for the operational footprint. Loans and investments are a separate figure, financed emissions in Scope 3 Category 15, not part of the branch number.
Per branch
- Electricity from the branch bill, including ATMs on the same meter.
- Diesel for the generator.
- Refrigerant top-ups from AC service invoices.
Rented premises
Most branches are rented. If the bank runs the space and pays the bill, the electricity is Scope 2 under operational control.
Keep financed emissions apart
Emissions of borrowers and investee companies go in Category 15 under the PCAF method. Report them separately from the branch footprint.
Worked example: one branch (one month, example inputs)
- Electricity: 3,500 kWh x 0.675 = 2,363 kg CO2
- Diesel: 150 litres x 2.68 = 402 kg CO2
- Branch total: 2,765 kg CO2 a month, 33.2 t a year
Example inputs; repeat for each branch from its own bills.
What Senseible does here
Senseible reads electricity bills (CEA grid factor 0.675 kg CO2 per kWh for FY 2025-26, CO2 Baseline Database version 22.0) and diesel, LPG and gas invoices (IPCC 2006 defaults) into a dated, fingerprinted Scope 1 and 2 record for each site. Intensity per unit uses the activity count you enter, and estimates are labelled as estimates.
Sources: GHG Protocol Corporate Standard, GHG Protocol Corporate Value Chain (Scope 3) Standard, CEA CO2 Baseline Database, version 22.0
Last reviewed 2026-10-21.