How do I calculate the carbon footprint of a call centre per seat?
Add the centre's electricity at 0.675 kg CO2 per kWh for FY 2025-26 and generator diesel at 2.68 kg per litre, then divide by production seats. Night shifts and 24-hour cooling raise use per seat, and employee cabs are a separate Scope 1 or Scope 3 line.
What to count
- Electricity for desks, IT, air conditioning and lights.
- Diesel for backup generators.
- Refrigerant top-ups for the AC plant.
Employee transport
Cabs the company runs are Scope 1; cabs from a vendor with drivers are Scope 3. Night-shift transport is often a large share of a BPO footprint.
Per seat
Divide by production seats, and by seat-hours for sites running different shift patterns.
Worked example: 400-seat centre (one month, example inputs)
- Electricity: 45,000 kWh x 0.675 = 30,375 kg CO2
- Diesel: 600 litres x 2.68 = 1,608 kg CO2
- Seats: 400
- Total: 31,983 / 400 = 80.0 kg CO2 per seat a month
Example inputs; use your bills and seat count.
What Senseible does here
Senseible reads electricity bills (CEA grid factor 0.675 kg CO2 per kWh for FY 2025-26, CO2 Baseline Database version 22.0) and diesel, LPG and gas invoices (IPCC 2006 defaults) into a dated, fingerprinted Scope 1 and 2 record for each site. Intensity per unit uses the activity count you enter, and estimates are labelled as estimates.
Sources: GHG Protocol Corporate Standard, CEA CO2 Baseline Database, version 22.0, IPCC 2006 Guidelines, Volume 2 Energy (fuel defaults)