Do I have to fill the CDP (formerly the Carbon Disclosure Project) question 7.16 country breakdown if all my plants are in India?
The table has one row for each country you selected in question 1.7, so an India-only supplier sees one row, and in my reading its figures should match your totals in 7.6 and 7.7. CDP calls a country breakdown best practice and does not accept negative figures.
What the table holds
For each country or area: Scope 1 in tonnes carbon dioxide equivalent (CO2e), Scope 2 location-based, and Scope 2 market-based. The rows are fixed and follow the countries you chose in question 1.7. The question is not shown to organisations in the financial services sector only. CDP's guidance does not say you may skip it; it calls the breakdown best practice.
Rules in CDP's guidance
- CDP considers a country or area breakdown best practice.
- Attribute emissions to the country where they actually occur and count in that country's inventory, whatever your financial presence there.
- Figures are gross, never negative, and for the reporting year only.
- If 100 percent of a country's emissions have been excluded from your disclosure, enter 0 for that country.
What this means for an India-only supplier
With a single country there is one row. My reading is that it should equal your gross Scope 1 in 7.6, and your Scope 2 figures in 7.7 for each method. If you add a country in 1.7 later, such as an overseas office, its row needs its own electricity bills and that country's grid factor.
Example: one plant in India, one office abroad
- India: Scope 1 320.0 tonnes. Scope 2 location-based: 560,000 kilowatt hours (kWh) x 0.675 (the Central Electricity Authority grid factor for FY 2025-26) = 378,000 kilograms (kg) = 378.0 tonnes.
- Overseas office: Scope 1 0 tonnes. Scope 2 location-based 12.0 tonnes, from its own bills and that country's factor.
- Country rows add to Scope 1 of 320.0 + 0 = 320.0 tonnes and Scope 2 location-based of 378.0 + 12.0 = 390.0 tonnes.
What Senseible does here
Senseible reads fuel invoices and electricity bills into monthly records, so the litres, kilowatt hours and months are in one place to copy from. An office abroad needs that country's grid factor from a published source.
- CDP 7.3: market-based Scope 2
- CDP 7.4: what counts as an exclusion
- CDP 7.22: group versus other entities
- Free calculators
Sources: CDP, Full Corporate Questionnaire Module 7 reporting guidance, April 2025 edition
Last reviewed 2026-11-05. CDP revises its questionnaire and guidance every year. Check the version your customer sent you before you answer.