Senseible

CEA weighted average vs combined margin: which grid factor do I use for my footprint?

For your carbon footprint, use the CEA weighted average emission factor. It describes the average power you actually drew from the grid. The operating, build and combined margin figures describe the power a project displaces, so they are for estimating project reductions and carbon credits, not for Scope 2.

What each CEA figure means

Why your inventory uses the weighted average

Location-based Scope 2 under the GHG Protocol Scope 2 Guidance asks for the average emission intensity of the grid where you consume power. The weighted average is exactly that. Using a margin figure would overstate a normal factory's Scope 2, because margins exclude the zero-carbon stations that are part of the power you buy.

When a margin figure is correct

What to record

  1. The factor type in words: weighted average or combined margin.
  2. The CEA database version and the fiscal year.
  3. Never mix types in one total. A footprint built on weighted average and a solar saving built on combined margin can sit side by side, labelled, but should not be added together.

What Senseible does here

Senseible uses the CEA weighted average factor, 0.675 kg CO2 per kWh for FY 2025-26 from version 22.0, for location-based Scope 2 on every electricity bill. It does not apply operating, build or combined margin factors.

Sources: CEA CO2 Baseline Database for the Indian Power Sector, User Guide, UNFCCC CDM Tool 07, Tool to calculate the emission factor for an electricity system, GHG Protocol Scope 2 Guidance

Last reviewed 2026-10-15.