Senseible

What efficiency should an industrial centrifugal fan or blower reach?

BEE gives peak efficiency ranges by fan type: 79 to 83% for airfoil, backward curved or inclined blades, 72 to 79% for modified radial, 69 to 75% for radial, 58 to 68% for pressure blowers and 60 to 65% for forward curved. Measure your fan's flow, pressure and shaft power and compare.

Peak efficiency by type

How to measure your fan

  1. Measure average velocity pressure across the duct with a pitot tube and inclined manometer, in mm water column.
  2. Velocity (m/s) = Cp x square root of (2 x 9.81 x velocity pressure / gas density). Use the pitot maker's Cp, or 0.85.
  3. Flow (m3/s) = velocity x duct area.
  4. Shaft power (kW) = electrical input (kW) x motor efficiency.
  5. Static efficiency (%) = flow x static pressure (mm WC) / (102 x shaft kW) x 100. Use total pressure for mechanical efficiency.

Usual fixes when a fan is low

Example: a backward curved process fan (illustrative)

Readings are illustrative.

What Senseible does here

Senseible tracks your plant's monthly units from bills, which shows whether a fan fix moved the total. It does not take fan readings.

Sources: BEE, Energy Conservation Guidelines for MSME Sector (2019): section 5.3 and Table 5.6 (from BEE guide book for energy managers and auditors, chapter 3.5)

Last reviewed 2026-10-24.