Our gas meter reading does not match the PNG bill. Which do we use?

Use the bill for emissions. The supplier corrects the raw meter volume for pressure and temperature to standard cubic metres, and states the calorific value used for billing. Your own reading is useful to check the bill, but it is not on the same basis until the same correction is applied.

From bill to CO2

  1. Billed volume in SCM, or energy in MMBTU.
  2. Times the calorific value on the bill to get energy, if not already given.
  3. Times about 56.1 kg CO2 per GJ, the IPCC default for natural gas.

When to question the bill

Keep

Bills, your own monthly readings and any supplier correspondence about disputed readings.