Should I use GCV or NCV when calculating CO2 from coal, gas or oil?

Use the calorific basis that matches your emission factor. IPCC 2006 factors per TJ are on net calorific value (NCV), so convert any gross (GCV) energy first: multiply by 0.95 for coal and oil, or 0.90 for natural gas. Skipping this overstates CO2 by about 5 percent for coal and oil and 11 percent for gas.

What the two values mean

Gross calorific value counts all the heat from burning a fuel, including the heat recovered when the water vapour in the flue gas condenses. Net calorific value leaves that heat out, because most boilers and furnaces send the vapour up the stack. The difference is larger for fuels rich in hydrogen, which is why natural gas has a wider gap than coal.

Indian coal grades, gas supplier bills and most fuel lab reports quote GCV. The IPCC tables and the EU's CBAM and ETS monitoring rules work on NCV.

The rule in one line

CO2 = energy on a GCV basis x the NCV to GCV ratio x a factor per unit of NCV energy. The IPCC 2006 Guidelines give default ratios of 0.95 for coal and oil and 0.90 for natural gas. A lab or supplier NCV is better than the default where you have one, as long as it is on the same moisture basis as the tonnes you burnt.

Where the mismatch slips in

When you do not need to convert at all

If you calculate from physical quantities with a per-unit factor, such as kg CO2 per litre, per kg or per scm, the calorific basis is already built into the factor. The conversion matters only when you work through energy, which is what you need for precise coal by grade, CBAM declarations, or comparing fuels for a switch.

Worked example: 100 tonnes of coal with a lab GCV of 4,500 kcal per kg

94.6 kg CO2 per GJ is the IPCC 2006 default for other bituminous coal. A lab NCV on an as-received basis replaces the 0.95 default.

What Senseible does here

Senseible applies per-unit IPCC 2006 factors to the quantity on the bill (for example 2.42 kg CO2 per kg of coal and 2.05 kg CO2 per scm of PNG), so ordinary fuel invoices need no GCV to NCV conversion. Keep lab GCV reports with your records where a buyer or regulator asks for an energy-based figure.

Sources: 2006 IPCC Guidelines, Volume 2 Energy, Chapter 1, section 1.4.1.2 (net and gross calorific values) and Table 1.4, Implementing Regulation (EU) 2023/1773, Annex III (CBAM monitoring on a net calorific value basis), on EUR-Lex, US EPA GHG Emission Factors Hub (factors per unit of higher heating value)

Last reviewed 2026-10-18.