How many standard cubic metres of natural gas does a gas engine or turbine need for one unit of electricity?

From the Petroleum Planning and Analysis Cell (PPAC) figure of 4,541 standard cubic metres (SCM) a day for 1 megawatt (MW) of generation, one kilowatt hour (kWh) takes about 0.189 SCM. A cross-check from PPAC's 1,720 kilocalorie (kcal) heat rate gives 0.191. A small engine below 50% efficiency needs more.

PPAC's inputs

The arithmetic

  1. 4,541 SCM per day / 24 hours = 189.2 SCM per hour for 1 MW, which is 1,000 kWh. So 0.1892 SCM per kWh.
  2. Cross-check from the heat rate: PPAC's NCV is 90% of GCV, so 9,000 kcal per SCM. 1,720 / 9,000 = 0.1911 SCM per kWh.
  3. The two differ by 1.0%. PPAC's 4,541 implies 24,000 x 1,720 / 4,541 = 9,090 kcal of net energy per SCM, slightly above the 90% rule. PPAC does not explain the gap.
  4. At a lower efficiency, scale up: SCM per kWh = 0.1892 x (50% / your efficiency), using net-basis (lower heating value) efficiency, as PPAC's heat rate is net. Engine datasheets may quote gross, so check.

Check your own engine

20,000 SCM of piped natural gas and 75,000 kWh in a month

The 2.05 and 2.12 kg per SCM are the two figures discussed on the natural gas calorific value page on this site, which explains why they differ by about 3%.

What Senseible does here

Senseible reads fuel invoices and electricity bills into monthly records, and keep both bills with the engine meter reading. The engine's own kWh meter reading is a separate number you will need to keep.

Sources: PPAC Ready Reckoner 2025-26, Table 9.5 Natural Gas Conversions (gas required for 1 MW, heat rate, GCV and NCV)

Last reviewed 2026-11-05. PPAC's figures are for a 50% efficient plant. Use your engine maker's heat rate or your own meters for a real site.