How much electricity and CO2 goes into a tonne of ice for fish handling?

Take the ice plant's metered kWh for a period, divide by tonnes of ice made in those days, and multiply by 0.710 kg CO2 per kWh. Then add generator diesel (2.68 kg CO2 per litre) and any HFC refrigerant top-ups. No Indian public benchmark exists, so your own meter and block count decide it.

Getting the two numbers right

A physics check on your figure

Freezing water takes about 334 kJ per kg, plus about 4.19 kJ per kg for each degree the water is cooled to 0 C and about 2.1 kJ per kg for each degree the ice is chilled below it. From 30 C water to ice at minus 5 C that is about 470 kJ per kg, or 131 kWh of cooling per tonne. The compressor's electricity is that cooling divided by the system's coefficient of performance, plus brine pumps, agitators and losses. A figure several times the theoretical value points to losses worth chasing: poor insulation, a fouled condenser or a wrong refrigerant charge.

Refrigerant and backup power

Who reports it

The ice plant owner reports its electricity as Scope 2 and diesel and HFC leaks as Scope 1. A seafood exporter or boat owner who buys ice reports it as Scope 3 Category 1. Give buyers your kg CO2 per tonne so they can multiply by the tonnes they bought.

Worked example: one month at a block ice plant (illustrative figures)

Plant figures are illustrative. Add DG diesel and any HFC top-ups for the month.

What Senseible does here

Senseible reads the ice plant's electricity bills for units and tariff and applies 0.710 kg CO2 per kWh, and reads DG diesel and refrigerant invoices. Dividing by tonnes of ice uses your production log.

Sources: CEA CO2 Baseline Database, version 21.0, GHG Protocol Corporate Standard (2004)