Which module datasheet numbers should I check before accepting rooftop solar: tolerance, fill factor and temperature coefficient?

The Ministry of New and Renewable Energy (MNRE) specification for residential rooftop systems sets a power tolerance of up to +3%, a minimum fill factor of 75% and a temperature coefficient of power equal to or better than -0.4% per degree Celsius for crystalline modules. It also lists the test standards a module must pass.

Numbers to find on the datasheet

These are clauses from the technical specification in Annexure 3 of MNRE's guidelines for its residential rooftop solar scheme, Pradhan Mantri Surya Ghar: Muft Bijli Yojana. A factory is not bound by them, but they are a published checklist to hold a quotation against.

Test standards the specification names

Labels you can check on the roof

Why the temperature number matters

Datasheet power is normally quoted at standard test conditions, which use a 25 degrees Celsius cell temperature (general practice, not printed in the cited clauses). A module on a hot factory roof can run far hotter, and the coefficient tells you how much power you lose for each degree above 25. A thin film module with -0.3% loses less than a crystalline one with -0.4% at the same heat.

A hot roof afternoon (example module)

Module power and cell temperature are example numbers. The two coefficients are MNRE's limits.

What Senseible does here

Senseible reads electricity bills into monthly records, so the units you import month by month sit in one place. It does not read datasheets or check module quality.

Sources: Ministry of New and Renewable Energy (MNRE), Guidelines for PM-Surya Ghar: Muft Bijli Yojana, Central Financial Assistance to Residential Consumers, with Annexures 2 to 4

Last reviewed 2026-11-06. Re-check clause numbers and figures against the current version of the guidelines before you rely on them. Clause numbers are from the technical specification in Annexure 3. Standards are revised, so check the current edition.