How do you prove an old machine's remaining lifetime for a CCTS offset project?
BEE's tool BM-T-015 offers three options: the manufacturer's technical lifetime compared with the first commissioning date, an expert evaluation, or default values. The default option needs proof the equipment was maintained as the supplier recommends, with no scheduled early replacement and no design fault or accident.
Why it matters
When a project replaces or retrofits existing equipment, credits can be limited by how long the old equipment would have kept running. If the project extends the life of equipment that stays in use, crediting is limited to the shortest estimated remaining lifetime.
The three options
- Manufacturer's information on technical lifetime, compared with the date of first commissioning.
- An expert evaluation.
- Default technical lifetime values, minus the operational time so far.
Rules to follow
- Determine remaining lifetime before the project is implemented and document it in the PDD.
- If you get a range, pick the conservative end, confirmed by the verifier.
- For relocated equipment, count its operating history at earlier sites too.
- Policy-driven replacement and changes in demand are not considered by this tool.