Why did EcoVadis not credit our energy and emissions figures?
EcoVadis credits energy consumption and greenhouse gas figures only if they cover at least 95% of the scope you are assessed on. Other reported figures need 80%. Numbers for your main plant alone, or a figure typed into the questionnaire with no supporting document, earn nothing.
The rule in EcoVadis's own methodology
Reporting counts only if it covers at least 80% of the scope of assessment, except energy consumption and greenhouse gas emissions, which must cover 95%. A separate rule says only questionnaire answers backed by a document are credited, and the document has to be linked to the right answer.
Five reasons a figure gets thrown out
- It covers one plant, and your scope includes a second plant, a warehouse or a head office.
- It leaves out a fuel: the diesel genset, the LPG furnace or the company vehicles.
- The document is a scanned photo. EcoVadis needs machine-readable files with real text, in PDF, DOCX, XLSX, JPG or PNG, under 30 MB.
- The document has no date, or does not show it belongs to your company.
- The figure is more than two years old. EcoVadis treats reported indicators as valid for two years.
Check your coverage before you submit
- List every site and entity in your EcoVadis scope, exactly as the questionnaire set-up shows it.
- For each site, collect 12 months of electricity bills and every fuel purchase: diesel, LPG, PNG, furnace oil, coal.
- Convert them: kWh times the CEA grid factor gives Scope 2; litres or kilograms of fuel times its factor gives Scope 1.
- Add up by site and see what share your figure covers. If any site is missing, get its bills before you submit; a partial figure is treated like no figure.
- Upload one dated summary that shows the total, the method and the sites covered, and link it to the energy and emissions answers.
A Rajkot pump-parts maker with two plants, FY 2025-26
- Plant 1 grid power: 360,000 kWh x 0.675 kg CO2/kWh = 243.0 t CO2.
- Plant 1 diesel genset: 6,000 L x 2.645 kg CO2/L = 15.9 t CO2.
- Plant 2 grid power: 150,000 kWh x 0.675 = 101.3 t CO2.
- Plant 2 LPG furnace: 4,000 kg x 2.98 kg CO2/kg = 11.9 t CO2.
- Company total: 372.0 t CO2. Plant 1 alone: 258.9 t, which is 69.6% of the total.
- Reporting Plant 1 only falls well short of 95%, so the figure scores nothing. Both plants together cover 100%.
Grid factor: CEA CO2 Baseline Database version 22.0 for FY 2025-26. Fuel factors: IPCC 2006 defaults. EcoVadis does not publish how it measures the 95%; share of emissions is a self-check, not its formula.
What Senseible does here
Upload a year of bills for every site and Senseible gives Scope 1 and 2 by site with the bill behind each line, so a missing plant shows up before EcoVadis finds it. Its team can then draft the energy and emissions answers from that record for you to review and submit.
- Get Scope 1 and 2 from your bills
- Carbon evidence EcoVadis asks for
- EcoVadis deadline: what to do first
- Questionnaire support
Sources: EcoVadis, Sustainability Rating methodology disclosure document (2026), CEA, CO2 Baseline Database for the Indian power sector, IPCC 2006 Guidelines, Volume 2: Energy
Last reviewed 2026-10-29. Re-check the 95% and 80% coverage thresholds, document rules and two-year data validity in each new EcoVadis methodology edition; update the CEA grid factor when a new version is published.