How much coke does heat recovery save on a Jagadhri brass pit furnace: 30%, 10% or 7.5%?

Not one figure. The Bureau of Energy Efficiency (BEE) Jagadhri manual says 30% of coke in its text, 10% in its table and 7.1 tonnes in its summary, for rupees (Rs) 0.30 lakh. The detailed project report says 7.2 tonnes, 7.5% and Rs 0.50 lakh. Each one's rupees fit only its 7.1 or 7.2 tonnes.

What each document prints

Which tonnes fit which rupees

Where 30% might come from

A gain of 5 percentage points on a furnace at about 11% efficiency cuts coke by roughly 31% (1 minus 11/16). So the text may be applying "5%" as points. That is my reading only. The detailed report says Jagadhri pit furnaces run at 8% to 15%, and the table then uses a third of that cut. Use the lower figures, 7.1 to 7.5%, until you have measured your own.

Two more differences to know

The same furnace, three readings (96 tonnes of coke a year)

Coke at the Intergovernmental Panel on Climate Change (IPCC) default for coke oven coke, 107,000 kilograms of CO2 per terajoule at 28.2 gigajoules a tonne, about 3.02 kilograms a kilogram; an estimate.

What Senseible does here

Self-serve, Senseible reads fuel invoices and electricity bills into monthly records; flue gas measurement is custom, on request. The coke bought each month is on file; compare it with the brass melted, from your own records, before and after you fit heat recovery.

Sources: BEE and Zenith Energy Services, Manual on energy conservation measures in brass and aluminium cluster, Jagadhri, BEE, Detailed project report: waste heat recovery for coke fired pit furnace, 600 kg, Jagadhri, IPCC 2006 Guidelines, Volume 2, Chapter 1 Introduction, IPCC 2006 Guidelines, Volume 2, Chapter 2 Stationary Combustion

Last reviewed 2026-11-06. Both documents are BEE publications for Jagadhri and print no year on the pages used. The reading of 30% as percentage points is the author's, and is labelled as one. The coke factor is an estimate.