Scopes, factors and calculations: questions answered
Pick the question closest to yours.
- The Alwar manual's motor sum says 10 hours a day and 7,000 hours a year. Which should I use?
- The Bureau of Energy Efficiency report for Punjab foundries puts a variable frequency drive on a 22 kilowatt screw compressor: why do its loading and unloading hours look swapped?
- The Chandigarh engineering profile of The Energy and Resources Institute (TERI) prints 20,417 tonnes of carbon dioxide (CO2) for 6.84 tonnes of liquefied petroleum gas (LPG): what is the right figure?
- The Chennai aluminium die casting profile lists four savings in tonnes of oil equivalent. What are they in tonnes of carbon dioxide (CO2) on today's factors?
- The Firozabad glass cluster profile prints two furnace tables with different counts: which should a unit or buyer quote?
- The Firozabad glass cluster profile's fuel bill column does not add to its printed total: which row is wrong?
- The Howrah galvanizing and wire drawing manual says the cluster could save rupees (Rs) 112,968,944 a year, but its table adds to more. Why?
- The Howrah galvanizing manual says its measures could cut about 517 tonnes of sulphur dioxide (SO2) a year if all are carried out. Is that right?
- The Intergovernmental Panel on Climate Change (IPCC) coal methane factor is per tonne of raw coal. How do I apply it to the washed coal I buy?
- The Intergovernmental Panel on Climate Change (IPCC) road default for diesel methane and nitrous oxide assumes 5 km per litre. Does that matter for an Indian truck doing 3.5?
- The IPCC gives 0.70 tonnes of carbon dioxide per tonne of direct reduced iron. Does that fit a coal fired sponge iron kiln?
- The Khurja potteries profile of The Energy and Resources Institute (TERI) says the cluster uses 18,442 tonnes of oil equivalent (toe) but its table total prints 16,192: which is right?
- The Ludhiana forging cluster profile gives 314,190 tonnes of carbon dioxide (CO2) a year. What factors sit behind it, and what is it on today's grid?
- The Ludhiana forging cluster profile says the energy bill is rupees (Rs) 27.2 crore, but its table says 2,720 million. Which one is right?
- The Mohali engineering profile of The Energy and Resources Institute (TERI) prints diesel in litres a month: does that tie to its 2,796 tonnes of oil equivalent (toe) a year?
- The Morbi manual gives slurry moisture going into the spray dryer as 35 to 40% in one place and 33 to 35% in another: which is right, and what does it cost in water to remove?
- The Morbi manual lists carbon dioxide savings for 17 projects: can I add them up into a cluster total?
- The Morbi manual's energy table shows a total of 3,345,800,000: what does that number mean, and which column should I use?
- The owner's car is used for both business and personal trips. How much of its fuel goes in Scope 1?
- The person who kept our carbon records is leaving. What should the handover cover?
- The Petroleum Planning and Analysis Cell lists firewood at 4,750 kilocalories a kilogram, but the Intergovernmental Panel on Climate Change says 15.6 megajoules. Which heat value should I use?
- The Rajkot forging cluster profile gives 2,641 tonnes of oil equivalent (toe) in its text and 3,641 in its table for the largest ring rolling unit: which is right?
- The Surendranagar ceramic profile prints 11,443 tonnes of carbon dioxide for the cluster: what factors did it use, and how do they compare with today's?
- The Thangadh profile prints turnover of about 150 crore rupees and energy figures that imply about 370,000 tonnes of product: do the two fit?
- The verifier asks for production records. What format do they need?
- The verifier asks how we set our organisational boundary. What do we show?
- The verifier asks to see our calculation workings. What should we hand over?
- The verifier asks why our emissions changed so much from last year. What do they want?
- The verifier raised findings on our emissions report. What do we do?
- The verifier wants a list of the emission sources we left out. Why, and what goes in it?
- The verifier wants a management representation letter. What is it?
- The verifier wants proof of where our emission factors come from. What do we show?
- The Virudhachalam profile prints rubber process oil at rupees (Rs) 3940,000 a kilolitre: what does its own bill table imply, and which fuel cost least for each unit of heat?
- The weighbridge weight of our coal trucks differs from the invoice. Which do we use?
- Two buyers' carbon tools gave us different figures from the same data. Which is right?
- Under open access, do I count units injected at the generator or units drawn at my factory for Scope 2?
- Under the Intergovernmental Panel on Climate Change (IPCC) rules, is a ship's voyage between two Indian ports domestic or international navigation?
- Vapi's chemical cluster profile prints two energy totals, 92,645 and 100,127 tonnes of oil equivalent (toe): which is right, and is its gas heat value per kg or per cubic metre?
- Virudhachalam ceramic and refractory kilns burn firewood, coal, petcoke and RPO: what is the cluster's footprint?
- Wankaner refractory units fire petcoke in tunnel kilns: what is the cluster's carbon footprint?
- We acquired another factory this year. Do we change our carbon base year?
- We are a buying agent on commission. Do the goods we source count in our emissions?
- We are switching our magnesium foundry's cover gas from sulphur hexafluoride (SF6) to a hydrofluorocarbon (HFC) such as HFC-134a or a fluorinated ketone: what do we report?
- We bought a factory partway through the year. How do we count its emissions?
- We burn biomass in our boiler. How does SBTi treat it in our target?
- We burn no fuel, but our buyer doubts our zero Scope 1. How do we show it?
- We buy diesel in jerry cans for forklifts and small engines. How do we record it for carbon?
- We buy electricity from a neighbouring factory's generator. What factor do we use?
- We buy hot rolled coil from a Dolvi steel works. What figure should we use for Scope 3?
- We buy LPG on one bill for both the canteen and the process. Do we need to split it?
- We buy pulp from Riau. What should we ask the mill for our Scope 3 figure?
- We do not want to hand our buyer our fuel and production records. What does the GHG Protocol suggest instead?
- We estimated December's electricity in our report. What do we do when the real bill arrives?
- We fill metered dose inhalers (MDIs) with a hydrofluorocarbon (HFC) propellant: what counts in our carbon figure?
- We found an error in last year's carbon footprint. Do we have to restate it?
- We get diesel delivered to our site by a doorstep delivery service. Is their receipt enough evidence?
- We have a steam flow meter. Can we calculate boiler emissions from steam instead of fuel?
- We have not surveyed staff. Can I estimate Category 7 from national commuting averages, the way the Greenhouse Gas Protocol's average-data method does?
- We have several electricity connections across our factory, office and godown. How do we count them for Scope 2?
- We have three plants. Should we report emissions per plant or as one company total?
- We hold a 26% stake in a joint venture we don't control. How do we report its emissions?
- We keep buying units. Should our reduction target use a fixed or a rolling base year?
- We lease 14 branch offices and shops and cannot get any energy data: how does the Scope 3 guidance let us estimate Category 8?
- We lease electric cars and vans from a fleet provider. Are their emissions Scope 1, 2 or 3?
- We lease laptops and servers instead of buying them. Which Scope 3 category do they go in?
- We moved goods by rail to cut emissions. How do we prove it to our buyer?
- We only have a few months of bills for our first carbon footprint. Can we still report it?
- We outsourced our delivery fleet to a transporter. Does the Greenhouse Gas Protocol say we must recalculate our base year?
- We paid for fuel in advance. Which year do the emissions go in?
- We pass some of our grid electricity to a neighbouring unit. Is that still our Scope 2?
- We pay a cold store per tonne to keep our produce. Is that Scope 3 Category 4 or Category 8?
- We reimburse staff for charging company EVs at home. Which scope is that?
- We rent a warehouse and the landlord pays the electricity. Is it our Scope 2 or Scope 3 Category 8?
- We rent desks in a co-working space with no meter. Is that Scope 2 or Scope 3?
- We rent out generators or construction equipment. Do we report the fuel our customers burn in them?
- We run our own locomotive in our railway siding. Is its diesel Scope 1?
- We sell our metal and plastic scrap. Does that reduce our carbon footprint?
- We sell products made for us under our brand by another factory. Who reports their emissions?
- We sell rice husk to a power plant. Can our mill claim the avoided emissions?
- We sell steel or aluminium scrap to recyclers. What goes in our Scope 3 Category 5 line for it?
- We store diesel in our own tank and issue it to DG sets and forklifts. How do we count it?
- We supply parts to a carmaker in Betim. How does Brazil's low-carbon grid affect our figure?
- We supply ten buyers who all want carbon data. Can we prepare it once?
- We use a cluster common facility centre for heat treatment or testing. Whose emissions are they?
- We use diesel or kerosene to wash parts, not to burn. Does it count in Scope 1?
- We use rooftop solar and grid power. What electricity factor do we give a buyer?
- What air ratio or flue gas oxygen should my furnace or boiler run at?
- What are Scope 1, Scope 2 and Scope 3, explained like I am running a kitchen?
- What are the 20-year and 100-year global warming potentials (GWP) of common refrigerants?
- What are the emissions from applying a tonne of urea on farms?
- What are the emissions from boiling and drying turmeric per tonne?
- What are the emissions of an e-waste dismantling unit?
- What are the emissions of running an ATM?
- What are the five data quality indicators a buyer may use to rate our Scope 3 data?
- What are the Intergovernmental Panel on Climate Change default calorific values in kilocalories per kilogram for the fuels I buy in India?
- What are the main CO2 sources in a soda ash plant using the Solvay process?
- What are the main emission sources at an aircraft MRO hangar?
- What are the most common carbon accounting mistakes Indian SMEs make?
- What are the seven steps of a GHG inventory quality system?
- What are the warning signs in a carbon footprint report from a consultant?
Earlier questions · More questions